Enkasonic® Installation Guidelines
|
![]() 1. Sound mat is loose laid over the entire concrete or wood subfloor.* * When using Acousti-Mat SD over corrugated steel deck, mat orientation must be in the same direction as the steel deck flutes. |
![]() 2. Isolation strips are installed, then taped, around the perimeter of the entire room, to eliminate flanking paths. Isolation strips are also installed, then taped, around any vertical penetration through the floor. |
![]() 3. Seams between sections of sound mat are adhered with zip-strips or taped.* *Once the mat has been loose laid, no further penetrations should be made. Rigid attachments through the sound mat minimizes the sound performance. |
||
|
|
|||
| Sound Mat | Underlayment Depth | Underlayment Depth with Reinforcement/Maxxon CSM |
| Acousti-Mat I | 3/4" (19 mm) | |
| Acousti-Mat II | 1" (25 mm) | 3/4" (19 mm) |
| Enkasonic | 1 1/2" (38 mm) | 1" (25 mm) |
| Acousti-Mat 3 | 1 1/2" (38 mm) | 1 1/2" (38 mm) |
| Acousti-Mat SD | 1 1/2" (38 mm) | 1 1/2" (38 mm) |