Level-Right®
Level-Right® Cementitious Underlayments can level any floor challenge.

Acousti-Mat® 3 Sound Ratings Maxxon Green Mark


Floor System Underlayment Insulation Ceiling Susp. on Chan. Ceiling Drywall Floor Coverings Rating Test Numbers
Acousti-Mat 3 over Open Beam
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon*
None
None
None
No
No
No
No
No
No
Vinyl
Wood Floating Floor
None
46 F-IIC
52 F-IIC
47 F-STC
02 31573.3
02 31573.4
02 31573.6
Bare Floor over Open Beam (control) None None No No None 33 F-IIC
30 F-STC
02 31573.5
02 31573.7
Acousti-Mat 3 over 8" Cast-in-Place Concrete (203 mm)
2" (51 mm) Maxxon*
None
No
No
None
65 F-IIC

03 56381.6
Bare Concrete,
no Acousti-Mat (control)
None None No No None 36 F-IIC 03 56381.1
Steel Joist
12" Deep (305 mm)

w/ 3/4" (19 mm) T&G plywood subfloor
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon*
1-1/2" (38 mm) Maxxon*
Yes
Yes
Yes
Yes
Yes
Yes
5/8" (16 mm)
5/8" (16 mm)
5/8" (16 mm)
Ceramic Tile
Vinyl
Wood
57 F-IIC
57 F-IIC
58 F-IIC
04-22-1
04-22-2
04-22-3
TJI® Joist w/ 3/4" (19mm)
T&G OSB Subfloor
1-1/2" (38 mm) Maxxon*

1-1/2" (38 mm) Maxxon*
Yes

Yes
Yes

Yes
2 layers 5/8"
  (2 x 16 mm)
2 layers 5/8"
  (2 x 16 mm)
Ceramic Tile

Ceramic Tile
58 F-IIC

59 F-STC
48-06-03

48-06-04
20" Open Web Truss w/ 3/4" (19mm) plywood subfloor 1-1/2" (38 mm) Maxxon*

1-1/2" (38 mm) Maxxon*

1-1/2" (38 mm) Maxxon*

1-1/2" (38 mm) Maxxon*

Yes

Yes

Yes

Yes
Yes

Yes

Yes

Yes
2 layers 5/8"
  (2 x 16 mm)
2 layers 5/8"
  (2 x 16 mm)
2 layers 5/8"
  (2 x 16 mm)
2 layers 5/8"
  (2 x 16 mm)
Ceramic Tile

Carpet and Pad

Hardwood

None
63 F-IIC

89 F-IIC

59 F-IIC

59 F-STC
R05200

*Approved Maxxon Underlayment

F-IIC (Field Impact Insulation Class) sound tests were performed in accordance with ASTM E 1007 and E989. F-STC (Field Sound Transmission Class) sound tests were performed in accordance with ASTM E 336 and E 413. Actual tests are available upon request. Maxxon Underlayments and Acousti-Mat II are but two components of an effective sound control system. No sound control system is better than its weakest component. Care must be taken in the installation of components of construction to assure the ultimate designed acoustical performance.



Maxxon provides underlayment, Gyp-Crete, gypsum concrete and other flooring underlayment products for new construction, remodeling and renovation.
This site and all contents copyright © 2001-2010 MAXXON Inc. All rights reserved.

 Home | Canada | Ireland | en français | en español